Specyfikacje
| Zasilanie | 12…33 V DC / 24 V AC ±15 %,< 7 mA |
|---|---|
| Wymiary zewnętrzne (szer. x wys. x gł.) | 24x55x mm |
| Analogue output load impedance 0…10v | > 10000 Ω |
| Zakres pomiarowy | 0…2500 kPa |
| Accuracy, resolution sensor | 0.1 % full scale % |
| Accuracy, long-term stability according to IEC EN 60770-1 | Max. ±0.25 % full scale % |
| Cabel | 1.5 m three-wire |
| Tolerable overload | ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale |
| Temperatura nośnika | -15…+125°C |
| Klasa ochrony | IP67 |
|---|---|
| Temperatura przechowywania | -50…100 °C |
| Waga wraz z opakowaniem | 0.9 kg |
| Media | Liquids and gases |
| (Well/Pressure) connection | G 1/4 “ |
| Złącze ciśnieniowe | Outside thread |
| Dynamic response time | < 2 ms, 1 ms typically |
| Material sealing | FPM |