Specifications
| Power Supply | 12…33 V DC / 24 V AC ±15 %,< 7 mA | 
|---|---|
| Dimensions, external (WxHxD) | 24x55x mm | 
| Analogue output load impedance 0…10v | > 10000 Ω | 
| Measuring range | 0…2500 kPa | 
| Accuracy, resolution sensor | 0.1 % full scale % | 
| Accuracy, long-term stability according to IEC EN 60770-1 | Max. ±0.25 % full scale % | 
| Cabel | 1.5 m three-wire | 
| Tolerable overload | ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale | 
| Media temperature | -15…+125°C | 
| Protection class | IP67 | 
|---|---|
| Storage temperature | -50…100 °C | 
| Weight, incl. packaging | 0.9 kg | 
| Media | Liquids and gases | 
| (Well/Pressure) connection | G 1/4 “ | 
| Pressure connection | Outside thread | 
| Dynamic response time | < 2 ms, 1 ms typically | 
| Material sealing | FPM | 

 Explosion-proof